TECHNICAL SPECIFICATION OF THICK - THIN
CONTROL UNIT
|
|||
|
|
|||
|
1. |
Pipe length Set :Total end to end length of PVC pipe is to be set by this thumbwheel. Generally Standard PVC pipe length is 600 cm (i.e. 6 meters). |
||
|
2. |
Leading end length set & Lagging end length set :- Length of thicker portion required at both ends namely Leading end & lagging end is to be set by 2-set of thumbwheels. |
||
|
3. |
% thickness set pot :- % of thickness to be increased can be set by this potentiometer & thickness can be increased upto 25% . |
||
|
4. |
Gear Ratio Selector: - Sometimes Traction unit is having different gear ratios & hence different Linear speed at maximum RPM of Motor. At factory unit is calibrated for 10 mts\min i.e. giving tacho input of 50V AC to IC 324 (so out put frequency is 600 Hz) and frequency divider is adjusted at '36' to get one pulse per one centimeter travel of PVC pipe on traction unit. |
||
|
5. |
Auto/Bypass: - When Switch is kept on bypass mode: instrument is bypassed: & there wont be any thickening and even if power supply is 'ON’. and when switch is in Auto Mode, automatic thickening will take place. |
||